genlp
genloop
Genloop · Sell · Siemens 501D5

Sell Your Siemens 501D5 Gas Turbine

Genloop buys Siemens and Westinghouse 501D5 and 501D5A gas turbines as principal, running, idle or mothballed, and handles the removal.

01 · The machine

A hundred megawatts at 60 Hz.

The 501D5 is a heavy-frame gas turbine that Westinghouse introduced at the start of the 1980s, rated at about 96 to 107 MW. The 501D5A followed in the mid-1990s at about 120 MW. Siemens bought the business in 1998 and later named the engine the SGT6-3000E. It turns at 3,600 rpm and serves 60 Hz grids.

Class
E-class
Heavy frame, later the SGT6-3000E
Output
96 to 121 MW
Simple cycle, D5 to D5A
Speed
3,600 rpm
Direct drive, no gearbox
Grid
60 Hz
Cannot be economically converted to 50 Hz
02 · What sets the value

What a buyer prices.

Two 501D5s with the same nameplate can be far apart in price. These are the reasons.

D5 or D5A

The D5 is rated at about 96 to 107 MW and the D5A at about 120 MW. Which one it is, and what has been uprated since, sets the starting point.

Cycle position

Equivalent hours and equivalent starts since the last hot gas path inspection and the last major, not total hours. The hot gas path interval users cite for the fleet is 24,000 equivalent hours or 900 equivalent starts.

Rotor

The fleet leaders had passed 235,000 hours by 2012. Siemens runs a rotor and casing inspection to justify operation beyond 100,000 hours, and a buyer asks whether yours has had it.

Combustion system

Most units run the DF42 combustor with water injection, and a few have dry low NOx burners. The permit a unit can meet decides where it can go.

Who can support it

Siemens’ current range no longer lists the model, but Siemens, Mitsubishi and independent repair shops support the fleet, and its users group still meets every year.

Controls and the package

Units were delivered on Westinghouse controls and many have since moved to T3000 or Ovation. The controls, the generator, the auxiliaries and the step-up transformer are priced with the turbine.

03 · Where it goes

Where a 501D5 goes next.

A block of 100 MW at 60 Hz that can be moved is useful to anyone who cannot wait for a new machine.

Industrial cogeneration

Process sites that need power and steam, the duty much of the fleet was built for.

Peaking capacity

Simple cycle capacity that runs a few hundred hours a year and is paid to be there.

Data center power

Baseload for sites whose load arrives before the grid connection does.

60 Hz markets

The Americas, Saudi Arabia, Korea, Taiwan, the Philippines and about half of Japan run at 60 Hz.

04 · What you get

Price certainty, and the equipment gone on the date the contract says.

No fee, no processGenloop buys as principal
One contractPurchase, removal, handback
Removal handledExecuted and insured by Genloop
A second lifeRestored, re-warrantied, redeployed
In execution nowThe register →
Combined-cycle asset7EA class CC · Latin America
Utility rebuild + capacity PPA6× Frame 7 · United States
Fleet divestment mandate600 MW recip · Southern hemisphere
05 · Questions

What Siemens 501D5 owners ask first.

The short answers. The detail is in the contract, and in the call that comes before it.

What is a used Siemens 501D5 worth?

It depends on whether it is a D5 or a D5A, where it sits in its maintenance cycle, the state of the rotor, its combustion system and controls, and whether it sells as a complete generating set. No public database records what used turbines actually sell for, so advertised prices are asking prices. Genloop makes a firm offer after its own engineers have inspected the unit.

Is a Westinghouse W501D5 the same as a Siemens SGT6-3000E?

Yes. W501D5, 501D5 and SGT6-3000E are names for the same engine. Westinghouse built it, Mitsubishi built it under license, and Siemens renamed it after buying the business in 1998. Genloop buys all of them.

Does Genloop buy 501D5s that are not running?

Yes. Genloop buys units that are running, idle or mothballed. A unit that has been mothballed for several years is looked at case by case.

Does Genloop buy the whole plant or only the turbine?

Either. Genloop buys a 501D5 as a complete generating set, with its generator, auxiliaries, controls and step-up transformer, or with the HRSG and steam turbine as a combined cycle or cogeneration block.

Can a 501D5 be moved to a 50 Hz grid?

No. The 501D5 turns at 3,600 rpm and makes 60 Hz, and it cannot be economically converted. Its buyers are in 60 Hz markets: the Americas, Saudi Arabia, Korea, Taiwan, the Philippines and about half of Japan.

Who handles dismantling and removal?

Genloop does. Dismantling, export compliance and transport are Genloop’s scope, insured throughout, and written into the same contract as the purchase. The site is handed back on the schedule the contract sets.

Does Genloop charge a fee?

No. Genloop buys as principal and takes title, so there is no fee, no marketing period and no waiting for a buyer to appear.

06 · Direct

Tell us about the asset.

Every enquiry is read by the people who inspect, value and buy the equipment, and answered directly. Owners rarely have everything; send what exists and Genloop fills the gaps on site.

What to send, if you have it
Nameplate and configuration

D5 or D5A, serial number, rating, fuel, and what is included: generator, transformer, HRSG, balance of plant.

Hours and starts

Equivalent hours and starts, trips, and the duty the unit ran: base load, cogeneration, peaking.

Inspection history

The last combustor, hot gas path and major inspections, with dates and open findings. Gaps are normal; say where they are.

Rotor, combustion and controls

Rotor hours and any rotor inspection, the combustion system, and the control system now fitted.

Site and removal constraints

The window in which the equipment must be gone, crane and road access, and any export or permit requirements.

Title and encumbrances

Who owns the equipment, and what has to be released at closing.